STANDARD OPERATING
PROCEDURE FOR FILTRATION OF THE RELEASED BULK SOLUTION.
Requirements:
v
Entire Pre-sterilized Unit, which includes
Pressure vessel, filling
v
vessels,
pre-sterilized membrane holder fitted with appropriate fiber
v
glass
filter of 1.5 micron followed by
membrane of appropriate porosity as per
product.
v
SS Clamps, Pre-sterilized Silicon Tubings.
v
Pre-sterilized Surgical Hand gloves and air vent
filter of 0.2 micron porosity.
v
Centralized supply of Nitrogen gas.
Precautions & Instructions :
v Pre-sterilized
units components must be handled with warring sterilized hand gloves.
v
Assembling of the filtration unit must be
carried out under laminar air flow lighted on
v
at least 15 minutes before starting actual
operation.
v
Bubble Point test must be carried out as per SOP
for checking the integrity of the
v
Membrane used before and after filtration
process.
Steps :
v Transfer
all the filtration equipment, vessels and related accessories to the filtration
area.
v Assembled
the filtration line in logical way.
v Carry
out the bubble point test, if found OK then only proceed for filtration
of the product as per schematic diagram.